545 research outputs found

    Chronic neural probe for simultaneous recording of single-unit, multi-unit, and local field potential activity from multiple brain sites

    Get PDF
    Drug resistant focal epilepsy can be treated by resecting the epileptic focus requiring a precise focus localization using stereoelectroencephalography (SEEG) probes. As commercial SEEG probes offer only a limited spatial resolution, probes of higher channel count and design freedom enabling the incorporation of macro and microelectrodes would help increasing spatial resolution and thus open new perspectives for investigating mechanisms underlying focal epilepsy and its treatment. This work describes a new fabrication process for SEEG probes with materials and dimensions similar to clinical probes enabling recording single neuron activity at high spatial resolution. Polyimide is used as a biocompatible flexible substrate into which platinum electrodes and leads are... The resulting probe features match those of clinically approved devices. Tests in saline solution confirmed the probe stability and functionality. Probes were implanted into the brain of one monkey (Macaca mulatta), trained to perform different motor tasks. Suitable configurations including up to 128 electrode sites allow the recording of task-related neuronal signals. Probes with 32 and 64 electrode sites were implanted in the posterior parietal cortex. Local field potentials and multi-unit activity were recorded as early as one hour after implantation. Stable single-unit activity was achieved for up to 26 days after implantation of a 64-channel probe. All recorded signals showed modulation during task execution. With the novel probes it is possible to record stable biologically relevant data over a time span exceeding the usual time needed for epileptic focus localization in human patients. This is the first time that single units are recorded along cylindrical polyimide probes chronically implanted 22 mm deep into the brain of a monkey, which suggests the potential usefulness of this probe for human applications

    Best practice in undertaking and reporting health technology assessments : Working Group 4 report

    Get PDF
    [Executive Summary] The aim of Working Group 4 has been to develop and disseminate best practice in undertaking and reporting assessments, and to identify needs for methodologic development. Health technology assessment (HTA) is a multidisciplinary activity that systematically examines the technical performance, safety, clinical efficacy, and effectiveness, cost, costeffectiveness, organizational implications, social consequences, legal, and ethical considerations of the application of a health technology (18). HTA activity has been continuously increasing over the last few years. Numerous HTA agencies and other institutions (termed in this report “HTA doers”) across Europe are producing an important and growing amount of HTA information. The objectives of HTA vary considerably between HTA agencies and other actors, from a strictly political decision making–oriented approach regarding advice on market licensure, coverage in benefits catalogue, or investment planning to information directed to providers or to the public. Although there seems to be broad agreement on the general elements that belong to the HTA process, and although HTA doers in Europe use similar principles (41), this is often difficult to see because of differences in language and terminology. In addition, the reporting of the findings from the assessments differs considerably. This reduces comparability and makes it difficult for those undertaking HTA assessments to integrate previous findings from other HTA doers in a subsequent evaluation of the same technology. Transparent and clear reporting is an important step toward disseminating the findings of a HTA; thus, standards that ensure high quality reporting may contribute to a wider dissemination of results. The EUR-ASSESS methodologic subgroup already proposed a framework for conducting and reporting HTA (18), which served as the basis for the current working group. New developments in the last 5 years necessitate revisiting that framework and providing a solid structure for future updates. Giving due attention to these methodologic developments, this report describes the current “best practice” in both undertaking and reporting HTA and identifies the needs for methodologic development. It concludes with specific recommendations and tools for implementing them, e.g., by providing the structure for English-language scientific summary reports and a checklist to assess the methodologic and reporting quality of HTA reports

    Bedload transport analysis using image processing techniques

    Get PDF
    Bedload transport is an important factor to describe the hydromorphological processes of fluvial systems. However, conventional bedload sampling methods have large uncertainty, making it harder to understand this notoriously complex phenomenon. In this study, a novel, image-based approach, the Video-based Bedload Tracker (VBT), is implemented to quantify gravel bedload transport by combining two different techniques: Statistical Background Model and Large-Scale Particle Image Velocimetry. For testing purposes, we use underwater videos, captured in a laboratory flume, with future field adaptation as an overall goal. VBT offers a full statistics of the individual velocity and grainsize data for the moving particles. The paper introduces the testing of the method which requires minimal preprocessing (a simple and quick 2D Gaussian filter) to retrieve and calculate bedload transport rate. A detailed sensitivity analysis is also carried out to introduce the parameters of the method, during which it was found that by simply relying on literature and the visual evaluation of the resulting segmented videos, it is simple to set them to the correct values. Practical aspects of the applicability of VBT in the field are also discussed and a statistical filter, accounting for the suspended sediment and air bubbles, is provided

    Raman microscopy of lithium-manganese-rich transition metal oxide cathodes

    Get PDF
    Lithium-rich and manganese-rich (LMR) layered transition metal (TM) oxide composites with general formula xLi2MnO3 • (1- x)LiMO2 (M = Ni, Co, Mn) are promising cathode candidates for high energy density lithium ion batteries. Lithium-manganese-rich TM oxides crystallize as a nanocomposite layered phase whose structure further evolves with electrochemical cycling. Raman spectroscopy is a powerful tool to monitor the crystal chemistry and correlate phase changes with electrochemical behavior. While several groups have reported Raman spectra of lithium rich TM oxides, the data show considerable variability in terms of both the vibrational features observed and their interpretation. In this study, Raman microscopy is used to investigate lithium-rich and manganese-rich TM cathodes as a function of voltage and electrochemical cycling at various temperatures. No growth of a spinel phase is observed within the cycling conditions. However, analysis of the Raman spectra does indicate the structure of LMR-NMC deviates significantly from an ideal layered phase. The results also highlight the importance of using low laser power and large sample sizes to obtain consistent data sets

    The chemical basis of mate recognition in two parasitoid wasp species of the genus Nasonia

    Get PDF
    To recognize one's mate is essential for all sexually reproducing animals. In insects, mate recognition is often based on chemical cues such as hydrocarbons which are distributed over the insect's cuticle. In the parasitoid wasp genus Nasonia (Hymenoptera: Pteromalidae), interspecific mating possibly occurs in microsympatry between Nasonia vitripennis Walker and Nasonia giraulti Darling despite post-zygotic isolation mechanisms preventing hybridization. Males of N. vitripennis are known to equally court con- and heterospecific females, which they recognize by means of cuticular hydrocarbons. A recent study surprisingly showed that this might not be the case in N. giraulti, leaving open how males of this species achieve the recognition of mating partners. In this study, we investigated chemical mate recognition in N. giraulti in more detail and compared observed behaviors with behaviors of N. vitripennis by conducting experiments with both species concurrently and under the same experimental conditions. We disentangled the role of female-derived non-polar cuticular lipids – i.e., cuticular hydrocarbons – and more polar cuticular lipids in the ability of males to recognize con- and heterospecific females. In addition, we tested whether females of the two species discriminate similarly between con- and heterospecific males. We demonstrate that, in contrast to N. vitripennis, males of N. giraulti prefer live conspecific females over heterospecific ones. Furthermore, in contrast to N. vitripennis, mate recognition in N. giraulti males is not based on cuticular hydrocarbons, but rather involves other chemical messengers, presumably more polar cuticular lipids. In both species, discrimination against heterospecific males decreases with female age

    Histological assessment of a chronically implanted cylindrically-shaped, polymer-based neural probe in the monkey

    Get PDF
    Objective. Previous studies demonstrated the possibility to fabricate stereo-electroencephalography probes with high channel count and great design freedom, which incorporate macro-electrodes as well as micro-electrodes offering potential benefits for the pre-surgical evaluation of drug resistant epileptic patients. These new polyimide probes allowed to record local field potentials, multi- and single-unit activity (SUA) in the macaque monkey as early as 1 h after implantation, and yielded stable SUA for up to 26 d after implantation. The findings opened new perspectives for investigating mechanisms underlying focal epilepsy and its treatment, but before moving to possible human application, safety data are needed. In the present study we evaluate the tissue response of this new neural interface by assessing post-mortem the reaction of brain tissue along and around the probe implantation site. Approach. Three probes were implanted, independently, in the brain of one monkey (Macaca mulatta) at different times. We used specific immunostaining methods for visualizing neuronal cells and astrocytes, for measuring the extent of damage caused by the probe and for relating it with the implantation time. Main results. The size of the region where neurons cannot be detected did not exceed the size of the probe, indicating that a complete loss of neuronal cells is only present where the probe was physically positioned in the brain. Furthermore, around the probe shank, we observed a slightly reduced number of neurons within a radius of 50 µm and a modest increase in the number of astrocytes within 100 µm. Significance. In the light of previous electrophysiological findings, the present data suggest the potential usefulness and safety of this probe for human applications

    Human anti-anthrax protective antigen neutralizing monoclonal antibodies derived from donors vaccinated with anthrax vaccine adsorbed

    Get PDF
    BACKGROUND: Potent anthrax toxin neutralizing human monoclonal antibodies were generated from peripheral blood lymphocytes obtained from Anthrax Vaccine Adsorbed (AVA) immune donors. The anti-anthrax toxin human monoclonal antibodies were evaluated for neutralization of anthrax lethal toxin in vivo in the Fisher 344 rat bolus toxin challenge model. METHODS: Human peripheral blood lymphocytes from AVA immunized donors were engrafted into severe combined immunodeficient (SCID) mice. Vaccination with anthrax protective antigen and lethal factor produced a significant increase in antigen specific human IgG in the mouse serum. The antibody producing lymphocytes were immortalized by hybridoma formation. The genes encoding the protective antibodies were rescued and stable cell lines expressing full-length human immunoglobulin were established. The antibodies were characterized by; (1) surface plasmon resonance; (2) inhibition of toxin in an in vitro mouse macrophage cell line protection assay and (3) in vivo in a Fischer 344 bolus lethal toxin challenge model. RESULTS: The range of antibodies generated were diverse with evidence of extensive hyper mutation, and all were of very high affinity for PA83~1 × 10(-10-11)M. Moreover all the antibodies were potent inhibitors of anthrax lethal toxin in vitro. A single IV dose of AVP-21D9 or AVP-22G12 was found to confer full protection with as little as 0.5× (AVP-21D9) and 1× (AVP-22G12) molar equivalence relative to the anthrax toxin in the rat challenge prophylaxis model. CONCLUSION: Here we describe a powerful technology to capture the recall antibody response to AVA vaccination and provide detailed molecular characterization of the protective human monoclonal antibodies. AVP-21D9, AVP-22G12 and AVP-1C6 protect rats from anthrax lethal toxin at low dose. Aglycosylated versions of the most potent antibodies are also protective in vivo, suggesting that lethal toxin neutralization is not Fc effector mediated. The protective effect of AVP-21D9 persists for at least one week in rats. These potent fully human anti-PA toxin-neutralizing antibodies are attractive candidates for prophylaxis and/or treatment against Anthrax Class A bioterrorism toxins

    Possibilities of alternative generation II biotests at Artemia

    Get PDF
    The meaning of alternative biotests is described and discussed. The paper also deals with the possible application of the developmental studies of the sea Artemia franciscana nauplinus. Five-day biotests including the validation criteria are described. The possibilities of the biotests are very wide. Additionally to the standard applications in ecotoxicology, there is a possibility of modelling pharmacological experiments or monitoring the effects of ionizing radiation and the interaction with other chemicals

    In vivo Recording Quality of Mechanically Decoupled Floating Versus Skull-Fixed Silicon-Based Neural Probes

    Get PDF
    Throughout the past decade, silicon-based neural probes have become a driving force in neural engineering. Such probes comprise sophisticated, integrated CMOS electronics which provide a large number of recording sites along slender probe shanks. Using such neural probes in a chronic setting often requires them to be mechanically anchored with respect to the skull. However, any relative motion between brain and implant causes recording instabilities and tissue responses such as glial scarring, thereby shielding recordable neurons from the recording sites integrated on the probe and thus decreasing the signal quality. In the current work, we present a comparison of results obtained using mechanically fixed and floating silicon neural probes chronically implanted into the cortex of a non-human primate. We demonstrate that the neural signal quality estimated by the quality of the spiking and local field potential (LFP) recordings over time is initially superior for the floating probe compared to the fixed device. Nonetheless, the skull-fixed probe also allowed long-term recording of multi-unit activity (MUA) and low frequency signals over several months, especially once pulsations of the brain were properly controlled

    Oscillatory activity in the medial prefrontal cortex and nucleus accumbens correlates with impulsivity and reward outcome.

    Get PDF
    Actions expressed prematurely without regard for their consequences are considered impulsive. Such behaviour is governed by a network of brain regions including the prefrontal cortex (PFC) and nucleus accumbens (NAcb) and is prevalent in disorders including attention deficit hyperactivity disorder (ADHD) and drug addiction. However, little is known of the relationship between neural activity in these regions and specific forms of impulsive behaviour. In the present study we investigated local field potential (LFP) oscillations in distinct sub-regions of the PFC and NAcb on a 5-choice serial reaction time task (5-CSRTT), which measures sustained, spatially-divided visual attention and action restraint. The main findings show that power in gamma frequency (50-60 Hz) LFP oscillations transiently increases in the PFC and NAcb during both the anticipation of a cue signalling the spatial location of a nose-poke response and again following correct responses. Gamma oscillations were coupled to low-frequency delta oscillations in both regions; this coupling strengthened specifically when an error response was made. Theta (7-9 Hz) LFP power in the PFC and NAcb increased during the waiting period and was also related to response outcome. Additionally, both gamma and theta power were significantly affected by upcoming premature responses as rats waited for the visual cue to respond. In a subgroup of rats showing persistently high levels of impulsivity we found that impulsivity was associated with increased error signals following a nose-poke response, as well as reduced signals of previous trial outcome during the waiting period. Collectively, these in-vivo neurophysiological findings further implicate the PFC and NAcb in anticipatory impulsive responses and provide evidence that abnormalities in the encoding of rewarding outcomes may underlie trait-like impulsive behaviour.RCUK, Wellcome, OtherThis is the final version of the article. It first appeared at http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0111300
    corecore